VSD ATV212-30kW-40HP-480V-3ph with EMC-IP21

Mfr. Part No.:

ATV212HD30N4

APT Stock No.:

SE-ATV212HD30N4

Brand:

SCHNEIDER ELECTRIC

In Stock: available

Need additional quantities?

Contact us for estimated lead time

Subtotal (1 unit)**

GHS 34,636.50

(Exc. VAT)

GHS 41,563.80

(Inc. VAT)

Available For Order

* Delivery dates may change based on your quantity and address.

Shipping & Policy

Payment Methods:

Momo Page imagemastercardvise

Shipping Cost:

Contact the supplier about freight and estimated delivery time.

Secure payments:

Every payment you make on aptghana.com is protected by the platform.

Return policy

Enjoy peace of mind with our 7-day return policy for used items, provided they are returned in their original packaging.

Centralized technical management

Instant viewing of the energy consumption

User-friendly

Compact size

Simple maintenance

Description

Compatible products

Specifications

Dimensions Drawings

Dimensions


Dimensions in mm

ATV212H

a

b

c

G

H

K

Ø

D22M3X

D22N4, D30N4

240

420

214

206

403

10

6

D37N4, D45N4

240

550

244

206

529

10

6

Dimensions in in.

ATV212H

a

b

c

G

H

K

Ø

D22M3X

D22N4, D30N4

9.45

16.54

8.43

8.11

15.87

0.39

0.24

D37N4, D45N4

9.45

21.65

9.60

8.11

20.83

0.39

0.24

EMC mounting plate (supplied with drive)


Dimensions in mm

ATV212H

b1

c1

D22M3X

D22N4, D30N4

122

120

D37N4, D45N4

113

127

Dimensions in in.

ATV212H

b1

c1

D22M3X

D22N4, D30N4

4.80

4.72

D37N4, D45N4

4.45

5.00


Mounting and Clearance

Mounting Recommendations
Clearance

Depending on the conditions in which the drive is to be used, its installation will require certain precautions and the use of appropriate accessories.

Install the unit vertically:

  • Do not place it close to heating elements.

  • Leave sufficient free space to ensure that the air required for cooling purposes can circulate from bottom to the top of the unit.


Mounting Types

Type A mounting


Type B mounting


Type C mounting


By removing the protective blanking cover from the top of the drive, the degree of protection for the drive becomes IP21. The protective blanking cover may vary according to the drive model, see opposite.


,
Specific Recommendations for Mounting in an Enclosure

To help ensure proper air circulation in the drive:

  • Fit ventilation grilles.

  • Check that there is sufficient ventilation. If there is not, install a forced ventilation unit with a filter. The openings and/or fans must provide a flow rate at least equal to that of the drive fans (refer to the product characteristics).

  • Use special filters with UL Type 12/IP54 protection.

  • Remove the blanking cover from the top of the drive.

Sealed Metal Enclosure (IP54 Degree of Protection)

The drive must be mounted in a dust and damp proof enclosure in certain environmental conditions, such as dust, corrosive gases, high humidity with risk of condensation and dripping water, splashing liquid, etc.This enables the drive to be used in an enclosure where the maximum internal temperature reaches 50°C.


Connections and Schema

Recommended Wiring Diagram
3-Phase Power Supply


A1:
ATV 212 drive
KM1:
Contactor
Q1:
Circuit breaker
Q2:
GV2 L rated at twice the nominal primary current of T1
Q3:
GB2CB05
S1, S2:
XB4 B or XB5 A pushbuttons
T1:
100 VA transformer 220 V secondary
(1)
Fault relay contacts for remote signalling of the drive status
(2)
Connection of the common for the logic inputs depends on the positioning of the switch (Source, PLC, Sink)
(3)
Reference potentiometer SZ1RV1202

NOTE: All terminals are located at the bottom of the drive. Install interference suppressors on all inductive circuits near the drive or connected on the same circuit, such as relays, contactors, solenoid valves, fluorescent lighting, etc.

Switches (Factory Settings)

Voltage/current selection for analog I/O (VIA and VIB)


Voltage/current selection for analog I/O (FM)


Selection of logic type


(1)
negative logic
(2)
positive logic


,
Other Possible Wiring Diagrams
Logic Inputs According to the Position of the Logic Type Switch

"Source" position


"Sink" position


"PLC" position with PLC transistor outputs


(1)
PLC


(1)
PLC

2-wire control


F:
Forward
R:
Preset speed
(2)
ATV 212 control terminals

3-wire control


F:
Forward
R:
Stop
RES:
Reverse
(2)
ATV 212 control terminals

PTC probe


(2)
ATV 212 control terminals
(3)
Motor

Analog Inputs

Voltage analog inputs

External +10 V


(2)
ATV 212 control terminals
(4)
Speed reference potentiometer 2.2 to 10 kΩ


(2)
ATV 212 control terminals

Analog input configured for current: 0-20 mA, 4-20 mA, X-Y mA


(2)
ATV 212 control terminals
(5)
Source 0-20 mA, 4-20 mA, X-Y mA

Analog input VIA configured as positive logic input ("Source" position)


(2)
ATV 212 control terminals

Analog input VIA configured as negative logic input ("Sink" position)


(2)
ATV 212 control terminals


Performance Curves

Derating Curves

The derating curves for the drive nominal current (In) depend on the temperature, the switching frequency and the mounting type (A, B or C).

For intermediate temperatures (45°C for example), interpolate between 2 curves.


X
Switching frequency


help mobile view

Need more information?

Check with our technical team!

Contact Us