ATV340- HD 45KW/60HP- ND 55KW/75HP- 400V-Ethernet

Mfr. Part No.:

ATV340D45N4E

APT Stock No.:

SE-ATV340D45N4E

Brand:

SCHNEIDER ELECTRIC

In Stock: available

Need additional quantities?

Contact us for estimated lead time

Subtotal (1 unit)**

GHS 58,217.54

(Exc. VAT)

GHS 69,861.05

(Inc. VAT)

Available For Order

* Delivery dates may change based on your quantity and address.

Shipping & Policy

Payment Methods:

Momo Page imagemastercardvise

Shipping Cost:

Contact the supplier about freight and estimated delivery time.

Secure payments:

Every payment you make on aptghana.com is protected by the platform.

Return policy

Enjoy peace of mind with our 7-day return policy for used items, provided they are returned in their original packaging.

Powerful dynamism for superior machine performance

Unprecedented automation performance

Reduced machine design time

Simplified machine engineering

Seamless automation integration

Description

Compatible products

Specifications

Dimensions Drawings

Dimensions
Views: Front - Left - Rear



Mounting and Clearance

Clearance


Dimensions in mm

X1

X2

X3

 100

 100

 10

Dimensions in in.

X1

X2

X3

 3.94

 3.94

 0.39


,
Mounting Types
Mounting Type A: Side by Side IP20


Possible, up to 50 °C, 2 drives only

Mounting Type B: Individual IP20


a
110 mm (4.33 in.)


Connections and Schema

Connections and Schema
Three-Phase Power Supply with Upstream Breaking via Line Contactor Without Safety Function STO

Connection diagrams conforming to standards ISO13849 category 1 and IEC/EN 61508 capacitySIL1, stopping category 0 in accordance with standard IEC/EN 60204-1.


(1)
Use relay output R1 set to operating state Fault to switch Off the product once an error is detected.
A1 :
Drive
KM1 :
Line Contactor
Q2, Q3 :
Circuit breakers
S1 :
Pushbutton
S2 :
Emergency stop
T1 :
Transformer for control part

Three-Phase Power Supply with Downstream Breaking via Switch Disconnector


(1)
Use relay output R1 set to operating state Fault to switch Off the product once an error is detected.
A1 :
Drive
Q1 :
Switch disconnector

Sensor Connection


It is possible to connect either 1 or 3 sensors on terminals AI1/AI3.


,
Control Block Wiring Diagram


(1)
Safe Torque Off
(2)
Analog Output
(3)
Digital Input
(4)
Reference potentiometer
(5)
Analog Input
(6)
Digital Output
(7)
0-10 Vdc, x-20 mA
(8)
0-10 Vdc, -10 Vdc...+10 Vdc
A1 :
ATV340 Drive
R1A, R1B, R1C :
Fault relay
R2A, R2C :
Sequence relay
R3A, R3C :
Sequence relay


,
Digital Inputs Wiring
Switch Set to SRC (Source) Position Using the Output Power Supply for the Digital Inputs


Switch Set to SRC (Source) Position and Use of an External Power Supply for the DIs


Switch Set to SK (Sink) Position Using the Output Power Supply for the Digital Inputs


Switch Set to EXT Position Using an External Power Supply for the DIs



,
Digital Outputs Wiring
Digital Outputs: Internal Supply

Positive Logic, Source, European Style, DQ switches to +24V


(1)
Relay or valve

Negative Logic, Sink, Asian Style, DQ switches to 0V


(1)
Relay or valve

Digital Outputs: External Supply

Positive Logic, Source, European Style, DQ switches to +24V


(1)
Relay or valve

Negative Logic, Sink, Asian Style, DQ switches to 0V


(1)
Relay or valve


Performance Curves

Open Loop Applications


1 :
Self-cooled motor: continuous useful torque
2 :
Force-cooled motor: continuous useful torque
3 :
Overtorque for 60 s maximum
4 :
Torque in overspeed at constant power


,
Closed Loop Applications


1 :
Self-cooled motor: continuous useful torque
2 :
Force-cooled motor: continuous useful torque
3 :
Overtorque for 60 s maximum
4 :
Torque in overspeed at constant power


help mobile view

Need more information?

Check with our technical team!