Modular timing relay, Harmony Timer Relays, 8A, 1CO, 0.1s..100h, multifunction, 12...240V AC DC
Mfr. Part No.:
RE17RMMW
APT Stock No.:
SE-RE17RMMW
Brand:
SCHNEIDER ELECTRIC
In Stock: available
Need additional quantities?
Contact us for estimated lead timeSubtotal (1 unit)**
GHS 726.00
(Exc. VAT)
GHS 884.99
(Inc. VAT)
Available For Order
* Delivery dates may change based on your quantity and address.
Shipping & Policy
Payment Methods:

Shipping Cost:
Contact the supplier about freight and estimated delivery time.
Secure payments:
Every payment you make on aptghana.com is protected by the platform.
Return policy
Enjoy peace of mind with our 7-day return policy for used items, provided they are returned in their original packaging.
Simplified panel design due to 17.5mm width same as 1-pole circuit breaker
Covers 0.1 s to 100 h timing eliminating the need to stock many different products
Flexible supply 12-240VAC/DC voltage, allowing automation system to remain stable during temporary voltage drops
Transparent cover to protect settings from being tampered with, reducing maintenance
Multi-functional: gives you flexibility in maintenance, reducing the variety of products to stock
Description
Shipping & Policy
Payment Methods:

Shipping Cost:
Contact the supplier about freight and estimated delivery time.
Secure payments:
Every payment you make on aptghana.com is protected by the platform.
Return policy
Enjoy peace of mind with our 7-day return policy for used items, provided they are returned in their original packaging.
Specifications
Dimensions Drawings

Connections and Schema

,

1) Contact Y1:
Control for functions B, C, Ac, Bw, Ad, Ah, N, O, W, T, Tt.
Partial stop for functions At, Ht and Pt.
Function D if Di selected.
Not used for functions A, H and P.
Technical Description
The timing period T begins on energisation. After timing, the output(s) R close(s). The second output can be either timed or instantaneous.


2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.)
,
After energisation of power supply and energization of Y1 causes the timing period T to start.
At the end of this timing period, the output(s) R close(s).
When deenergization of Y1, the timing T starts.
At the end of this timing period T,the output(s) R revert(s) to its/their initial position.
The second output (R2) can be either timed (when set to "TIMED") or instantaneous (when set to "INST").


,
After power-up, the first opening of control contact C starts the timing. Timing can be interrupted each time control contact closes. When the cumulative total of time periods elapsed reaches the pre-set value T, the output relay closes.

T = t1 + t2 +...
,
After power-up, pulsing or maintaining control contact C starts the timing T. The output R closes for the duration of the timing period T then reverts to its initial state.

,
On closing and opening of control contact C, the output R closes for the duration of the timing period T.

,
After power-up and closing of the control contact C, the output R closes. When control contact C re-opens, timing T starts. At the end of the timing period, the output(s) R revert(s) to its/their initial state. The second output can be either timed or instantaneous.


2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.)
,
On energisation of power supply, output(s) R starts at its/their initial state for timing duration T then change(s) to output(s) R close(s) for the same timing duration T.This cycle is repeated indefintely until power supply removal.Specially for RE17*, RE22R2AMU, RE22R2MMW, RE22R2MMU, RE22R2MJU,this D function can only be initiated by energizing Y1 permanently.The second output (R2) can be either timed (when set to "TIMED") or instantaneous (when set to "INST").




,
Repetitive cycle with two timing periods T of equal duration, with output(s) R changing state at the end of each timing period T.
The second output can be either timed or instantaneous.


2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.)
,
On energisation of the relay, timing period T starts and the output(s) R close(s). At the end of the timing period T, the output(s) R revert(s) to its/their initial state. The second output can be either timed or instantaneous.


2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.)
,
On energisation of power supply, output(s) R close(s) and timing period T starts.
The timing can be interrupted / paused each time X1 energizes.
When the cumulative total of time periods elapsed reaches the pre-set value T, the output(s) R revert(s) to its/their initial state Reenergization of X1 will also cause output(s) R close(s) if the time has elapsed and restart the same operation as described at the beginning.
Except for RE17*, RE22R2MMW, RENF22R2MMW, RE22R2MMU and RE22R2MJU, timing can be interrupted / paused each time Y1 energizes.
The second output (R2) can be either timed (when set to "TIMED" or instantaneous (when set to "INST").

T = t1 + t2 +...

T = t1 + t2 +...

T = t1 + t2 +...

T = t1 + t2 +...
,
Relay de-energised
Relay energised
Output open
Output closed
C | Control contact |
G | Gate |
R | Relay or solid state output |
R1/R2 | 2 timed outputs |
R2 inst. | The second output is instantaneous if the right position is selected |
T | Timing period |
Ta - | Adjustable On-delay |
Tr - | Adjustable Off-delay |
U | Supply |