Pump control relay RM35-BA - range 1..10 A
Mfr. Part No.:
RM35BA10
APT Stock No.:
SE-RM35BA10
Brand:
SCHNEIDER ELECTRIC
In Stock: available
Need additional quantities?
Contact us for estimated lead timeSubtotal (1 unit)**
GHS 1,485.30
(Exc. VAT)
GHS 1,782.36
(Inc. VAT)
Available For Order
* Delivery dates may change based on your quantity and address.
Shipping & Policy
Payment Methods:

Shipping Cost:
Contact the supplier about freight and estimated delivery time.
Secure payments:
Every payment you make on aptghana.com is protected by the platform.
Return policy
Enjoy peace of mind with our 7-day return policy for used items, provided they are returned in their original packaging.
Simplified panel design due to 35mm width same as 3-pole circuit breaker
Experience unprecedented accuracy, predictive maintenance, and superior security.
Provides automatic shutdown management and fault information for a quick fault identification and troubleshooting
Transparent cover to protect settings from being tampered with reducing maintenance
Compatible with a wide range of applications, such as hoisting, packaging, lifts, textile, pumping, and water.
Description
Shipping & Policy
Payment Methods:

Shipping Cost:
Contact the supplier about freight and estimated delivery time.
Secure payments:
Every payment you make on aptghana.com is protected by the platform.
Return policy
Enjoy peace of mind with our 7-day return policy for used items, provided they are returned in their original packaging.
Specifications
Dimensions Drawings

Connections and Schema
3-phase < 10 A

Single-phase ∼ 230 V < 10 A

3-phase > 10 A

Single-phase ∼ 230 V > 10 A

Technical Description
This mode is designed to control a pump via an external signal. The relay output is closed when the signal is present at Y1 (contact closed). Y2 can be used to reset the relay after a current fault.

This mode is designed to control a pump via two external control signals (Y1 and Y2). The output relay closes when both input signals are present (Y1 and Y2 closed).

If the control relay is configured for a single-phase supply, it monitors the current consumed by the pump. If the control relay is configured for a 3-phase supply, it monitors the current, phase sequence and phase failure.
Overcurrent detection

Undercurrent Detection

Ti Time delay to inhibit fault monitoring on starting of pump
Tt Time delay in the event of a fault
Un 3-phase or single-phase power supply
I Monitored current
I < Undercurrent threshold
I > Overcurrent threshold
I. Def Presence of a current fault
11-12, 11-14 Output relay connections
Relay status: black color = energized.