Pendant control station XAC- 6 PB NO + 1 EMG Stop
Mfr. Part No.:
XACA6714
APT Stock No.:
SE-XACA6714
Brand:
SCHNEIDER ELECTRIC
In Stock: available
Need additional quantities?
Contact us for estimated lead timeSubtotal (1 unit)**
GHS 1,534.95
(Exc. VAT)
GHS 1,841.94
(Inc. VAT)
Available For Order
* Delivery dates may change based on your quantity and address.
Shipping & Policy
Payment Methods:

Shipping Cost:
Contact the supplier about freight and estimated delivery time.
Secure payments:
Every payment you make on aptghana.com is protected by the platform.
Return policy
Enjoy peace of mind with our 7-day return policy for used items, provided they are returned in their original packaging.
Description
This pistol grip shaped pendant control station is ideal for direct control with heavy work gloves of mechanical handling applications such as overhead cranes, tower cranes, fixed hoists and beam hoists It is shock and corrosion resistant thanks to its rugged, double insulated thermoplastic material Its high endurance allows for 1 million operations
Shipping & Policy
Payment Methods:

Shipping Cost:
Contact the supplier about freight and estimated delivery time.
Secure payments:
Every payment you make on aptghana.com is protected by the platform.
Return policy
Enjoy peace of mind with our 7-day return policy for used items, provided they are returned in their original packaging.
Specifications
Dimensions Drawings
Below drawing shows a product with 6 cut-outs. Select the number of cut-outs according to the product characteristics in order to get b, b1 and c dimensions.

(1) For 2 and 3-way XAC A stations.
(2) For 4 to 8-way XAC A stations.
(3) With trigger action Emergency stop head operator
(4) Internal ø
Dimensions in mm
Number of cut-outs | 2 | 3 | 4 | 5 | 6 | 8 | 12 |
|---|---|---|---|---|---|---|---|
b | 314 | 314 | 440 | 440 | 500 | 560 | 680 |
b1 | 190 | 190 | 250 | 250 | 310 | 370 | 490 |
c | 80 | 80 | 80 | 80 | 80 | 80 | 92 |
Dimensions in in.
Number of cut-outs | 2 | 3 | 4 | 5 | 6 | 8 | 12 |
|---|---|---|---|---|---|---|---|
b | 12.36 | 12.36 | 17.32 | 17.32 | 19.68 | 22.05 | 26.77 |
b1 | 7.48 | 7.48 | 9.84 | 9.84 | 12.20 | 14.57 | 19.29 |
c | 3.15 | 3.15 | 3.15 | 3.15 | 3.15 | 3.15 | 3.62 |
Connections and Schema
With ZBE2BE101 + ZB2BE102 contacts blocks, to be ordered separately

Performance Curves
Operating rate: 3600 operating cycles/hour. Load factor: 0.5.
Millions of operating cycles, AC-15 utilization category

Ithe Thermal current
(A) Current
Operating rate: 3600 operating cycles/hour. Load factor: 0.5.
Power broken in W for 1 million operating cycles, DC-13 utilization category
Voltage | V | 24 | 48 | 120 |
|---|---|---|---|---|
Inductive circuit | W | 65 | 48 | 40 |