schneider-electric lv429492 Picture
schneider-electric logo

Earth-leakage VigiPacT add-on protection module, ComPacT NSX 250, 200VAC to 440VAC, 30mA to 30A, 3 poles

Mfr. Part No.:

LV429492

APT Stock No.:

SE-LV429492

Brand:

Schneider Electric

Back Order

Subtotal (1 unit)**

GHS 7,772.57

(Exc. VAT)

GHS 9,474.76

(Inc. VAT)

Available For Order

* Delivery dates may change based on your quantity and address.

Shipping & Policy

Payment Methods:

Momo Page imagemastercardvise

Shipping Cost:

Contact the supplier about freight and estimated delivery time.

Secure payments:

Every payment you make on aptghana.com is protected by the platform.

Return policy

Enjoy peace of mind with our 7-day return policy for used items, provided they are returned in their original packaging.

Schneider Electric green signature style for the entire ComPacT range

Estimated 40% reduction of wiring time for panel builders

Experience easier installation thanks to a new ergonomic front-plate design

Gain the confidence that all auxiliaries are on the right spot

Ergonomic new toggle for easier breaker manual operation

Description

This is a Vigi add-on module for ComPact NSX 250 that provides an earth-leakage protection. It is used for 3 poles circuit breakers. The operational rated voltage is between 200 and 440 VAC 50/60 Hz. The earth-leakage sensitivity is adjustable from 30 mA to 30 A. It is installed directly on the device terminals and directly actuates the trip unit in case of earth-leakage default. This Vigi add-on module is self-powered internally by the distribution-system voltage, even is supplied by only 2 phases. It is compliant with IEC 60947-2 standard, annex B.

Specifications

Main
Range of product
ComPacT NSX100...250
ComPact NSX100...250
Device short name
VigiPacT
Product or component type
Vigi add-on
Device application
Wiring
Range compatibility
ComPacT ComPacT NSX250 circuit breaker
ComPact ComPact NSX250 circuit breaker
Poles description
3P
[In] rated current
250 A
Earth-leakage protection class
Class A
Class AC
Residual earth-leakage sensitity adjustment type
Adjustable
Earth-leakage sensitivity
0.03 A for class A
0.1 A for class A
0.3 A for class A
0.5 A for class A
1 A for class A
3 A for class A
10 A for class AC
30 A for class AC
Residual earth-leakage time delay adjustment type
Adjustable
[Δt] residual earth-leakage time delay adjustment
0 ms
60 ms
150 ms
300 ms
500 ms
800 ms
1.2 s
4 s
Complementary
Network type
AC
Network frequency
50/60 Hz
[Ue] rated operational voltage
200...440 V AC 50/60 Hz conforming to IEC 60947-2
Earth-leakage protection
With
Maximum breaking time
800 ms
Overvoltage category
IV